A precision water bath is for work where a few tenths of a degree change the result. This one has a stirrer with a speed regulator to keep the water even. A mercury contact thermometer switches the heater with a sensitivity of 0.2 °C. Glass windows on two opposite sides let you watch a viscometer or a sample from the side without lifting it out.

Specifications

ObservationGlass windows on two opposite sides
Temperature controlMercury contact thermometer, sensitivity 0.2 °C
StirrerFitted, with speed control regulator
Chamber sizes425 x 250 x 225 mm (17 x 10 x 9 in), 450 x 375 x 375 mm (18 x 15 x 15 in), 600 x 450 x 450 mm (24 x 18 x 18 in)
Supply220 V AC, 50 Hz, single phase
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Physical Chemistry Practicals

The acid hydrolysis of methyl acetate is a standard kinetics practical. Students keep the reaction flask in the bath and withdraw a sample at timed intervals. Each sample is run into ice-cold water to slow the reaction and titrated against alkali from a Burette. The rise in titre with time gives the rate constant, and a second run at another setting shows the effect of temperature.

For relative density, a Specific Gravity Bottle filled with the liquid is held in the bath until it reaches the bath temperature, then dried and weighed. Through the side windows, students can also time the fall of a liquid between the marks of a capillary viscometer clamped upright in the water.

Frequently Asked Questions

What does a mercury contact thermometer do?
It is a thermometer and a switch in one. When the mercury column reaches a contact wire set at the chosen temperature, it closes a circuit that turns the heater off through a relay. As the water cools and the column drops, the heater comes back on.

Why does the bath have windows on two sides?
With glass on opposite sides, light passes straight through the water. You can watch a meniscus pass the marks of a viscometer, or a colour change in a flask, while the apparatus stays at the bath temperature.

Why does close temperature work need a stirrer?
Still water forms warmer and cooler layers, with the warmest water near the heater and at the top. The stirrer mixes it so every part of the chamber stays close to the setting. Run it fast enough to mix but not so fast that it shakes the glassware.

Which chamber size should I choose?
The 425 x 250 x 225 mm chamber holds one or two viscometers or flasks. The two larger chambers suit a class running several sets at once. They also take tall apparatus that must sit deep in the water.

How do I bring the bath to an exact setting?
Hang a separate thermometer in the water near your sample and wait until it stops changing. Adjust the contact thermometer in small steps, since each change needs a few minutes before the water settles again.