Water Bath Tissue Flotation Manufacturer,Supplier and Exporter in India
Product Code : EL-B-1957
Jlab Export is a leading Water Bath Tissue Flotation Manufacturer,and suppliers in India
After a paraffin block is cut on a microtome, the thin ribbon of sections comes off creased and folded. A tissue flotation bath holds water a few degrees below the melting point of the wax. Each section floats flat on the warm surface and can then be picked up on a slide. This bath is made for pharmaceutical and biomedical laboratories and is simple to run.
Specifications
| Use | Floating paraffin tissue sections flat before mounting on slides |
| Used in | Pharmaceutical and biomedical laboratories |
| Build | Sturdy construction, simple to operate, low maintenance |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Section Mounting Practice for Students
In histology classes, students cut a trimmed block on a Rotary Microtome and carry the ribbon to the bath on a wet brush. They lay it on the water shiny side down and let the warmth open out the creases. One section is then parted from the ribbon with a needle and lifted from below onto one of the Microscope Slides, held at a slant.
Teachers can float two ribbons, one on water that is too cool and one at the right setting, so the class sees the folds stay in or open out. The mounted slides drain upright and then go to a Slide Warming Table to dry before dewaxing and staining.
Frequently Asked Questions
Why do sections spread apart or break up on the water?
The water is too warm for the wax. As the wax softens, the section stretches unevenly and the tissue tears away from it. Lower the setting until sections flatten in a few seconds and then hold their shape.
Should I fill the bath with distilled water?
Yes. Tap water leaves scale and carries dust and fine bubbles that end up under the section. Use fresh distilled water each day, and draw a strip of paper across the surface to lift off stray bits of wax.
Why must the slide be clean before it picks up a section?
Grease on the glass stops the section from sticking evenly, so it can lift off later in the stain baths. Use clean, grease-free slides, and many labs coat them with a thin adhesive such as albumin first.
Can ribbons from any microtome be floated?
Yes, as long as the sections are cut from paraffin blocks. Rotary, sledge and hand microtomes all give ribbons or single sections that can be floated. Frozen sections are handled differently and are not floated on warm water.
Other Histology Equipment
- Paraffin Section Flotation Bath (section flotation bath with PTFE-coated interior)
- Tissue Flotation Bath (225 mm)
- Paraffin Embedding Bath
- Staining Jars
For a quote, use Add To Cart or send us a message through the contact page.