Slide Warming Table

Product Code : EL-HP-2065
Jlab Export is a leading Slide Warming Table Manufacturer,and suppliers in India

A slide warming table keeps freshly mounted microtome sections at a gentle, even warmth, so they stretch out flat and dry onto the slide before staining. The top is highly polished copper or stainless steel sheet on a mild steel body in stoving enamel. A thermostatic control knob sets the warmth, an indicator lamp shows it is on, and it runs on 220 V AC.

Specifications

TopHighly polished copper or stainless steel sheet
BodyThick mild steel, stoving enamel finish
Temperature controlThermostatic, from ambient
Sizes30 x 25 cm (12 x 10 in), 45 x 30 cm (18 x 12 in), 60 x 15 cm (24 x 6 in)
FittingsThermostatic control knob, indicator lamp, cord and plug
Power supply220 V AC, 50 Hz, single phase
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Histology Practicals with the Warming Table

The warming table is the last stop before staining in a paraffin section class. Students cut sections on a Sliding Microtome, flatten them on a Tissue Flotation Bath (225 mm) and pick each one up on one of the Microscope Slides. After draining, the slides go onto the warm top in rows.

A simple comparison shows why this step matters. Half the slides of a batch dry on the table and the rest are left on the bench at room temperature. Both sets then pass through the stain baths in Staining Jars, and students count how many sections stay in place and lie flat.

Frequently Asked Questions

What temperature should the warming table be set to?
Set it a little below the melting point of the paraffin wax used for embedding. That warmth flattens and dries the section without melting the wax around the tissue. Check the top with a thermometer when you first set the thermostat.

How long should slides stay on the table?
Leave them until all the water under the section has dried and the section lies flat and clear. The time depends on section thickness and room conditions, and many labs finish drying in an oven before staining.

Copper or stainless steel top: which should I choose?
Copper spreads heat quickly and evenly across the top but tarnishes with time. Stainless steel stays bright and is easy to wipe clean. Both tops are highly polished, so slides move on and off smoothly.

What happens if the table runs too hot?
The wax softens around the tissue, so the section can slide or crease before it has stuck to the glass. Long drying at high heat can also crack the section and give the nuclei a bubbly look after staining. Turn the thermostat down and lift slides off once they are dry.

Which size of table should a lab choose?
The 30 x 25 cm and 45 x 30 cm tables hold rows of slides for a class batch. The long, narrow 60 x 15 cm table fits beside a microtome on a narrow bench and takes slides in a long row.