• +91-85699-09696

categories

Switchboard Panel, Ammeters, Voltmeters, Rectifier Type Manufacturer, Suppliers and Exporter in India

Jlabexport is a leading Switchboard Panel, Ammeters, Voltmeters, Rectifier Type Manufacturer,and suppliers in India, United States, Indonesia, Brazil, Bangladesh, Mexico, Japan, Egypt, Philippines, Democratic Republic of the Congo, Vietnam, Iran, Turkey, Tanzania, United Kingdom, France, South Africa, Italy, Kenya, Colombia, Sudan, Uganda, South Korea, Argentina, Afghanistan, Yemen, Angola, Morocco, Poland, Uzbekistan, Mozambique, Malaysia, Ghana, Saudi Arabia, Peru, Madagascar, Côte d’Ivoire, Cameroon, Niger, Venezuela, Australia, Syria, Mali, Burkina Faso, Sri Lanka, Malawi, Zambia, Chad, Kazakhstan, Somalia, Chile, Senegal, Ecuador, Cambodia, Zimbabwe, Guinea, Benin, Rwanda, Burundi, Bolivia, South Sudan, Tunisia, Haiti, Belgium, Dominican Republic, Jordan, United Arab Emirates, Honduras, Tajikistan, Papua New Guinea, Portugal, Togo, Sierra Leone, Belarus, Laos, Turkmenistan, Libya, Kyrgyzstan, Nicaragua, Paraguay, Bulgaria, Serbia, Republic of the Congo, Lebanon, Liberia, Central African Republic, Palestine, Oman, Mauritania, New Zealand, Costa Rica, Kuwait, Panama, Croatia, Georgia, Eritrea, Mongolia, Uruguay, Qatar, Namibia, Bosnia and Herzegovina, Moldova, Armenia, Gambia, Jamaica, Lithuania, Albania, Gabon, Botswana, Lesotho, Guinea-Bissau, Slovenia, Equatorial Guinea, Latvia, North Macedonia, Bahrain, Trinidad and Tobago, Timor-Leste, Cyprus, Estonia, Eswatini, Mauritius, Djibouti, Fiji, Comoros, Solomon Islands, Guyana, Bhutan, Luxembourg, Suriname, Montenegro, Malta, Maldives, Cabo Verde, Brunei, Belize, Bahamas, Iceland, Vanuatu, Barbados, São Tomé and Príncipe, Samoa, Saint Lucia, Kiribati, Seychelles, Grenada, Saint Vincent and the Grenadines, Antigua and Barbuda.

Last updated: 13 November 2026

What Are Switchboard Panel Ammeters and Voltmeters?

Switchboard panel meters are analog ammeters, voltmeters and galvanometers that are fitted into control panels, power supplies and lab training boards to show current and voltage at a glance. This range has five listings. They cover ammeters from 0–1 mA up to 30 A, voltmeters from 0–20 mV up to 500 V, moving-coil DC meters in three flush cases, and centre-zero galvanometers. One listing gives the high-voltage withstand and insulation rating of the meters. Panel builders, electrical labs and training institutes buy them. JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India, makes them.

Request a quotation  |  Compare the meters  |  See the tasks covered

Which Meters Are in the Switchboard Panel Range?

GroupItemsWhat it covers
Ammeters and Voltmeters3Current meters in milliampere and ampere ranges, voltage meters in millivolt and volt ranges, and moving-coil DC meters in round and rectangular flush cases.
Centre-Zero Galvanometers1Meters with 30–0–30 and 50–0–50 scales that show which way a current flows as well as its size.
High Voltage Test Rating1The withstand and insulation figures that the listing gives for all instruments of the range.

Compare Switchboard Panel Meters by Range and Case

Each table sets out the meters of one group, using the ranges, cases and construction given on each product page.

Ammeters and Voltmeters (3)

MeterMeasuresRangesCaseMovement
AmmetersCurrent0–1 mA to 750 mA; 0–1 A to 30 ANot listedNot listed
VoltmetersVoltage0–20 mV to 750 mV; 0–1 V to 500 VNot listedNot listed
DC Ammeters and VoltmetersDC current and DC voltageNot listed85 mm round, 100 mm round or 110 x 90 mm, flush mountingMoving coil on a suspension system

The DC meters also have a magnetic circuit that blocks outside magnetic fields and a temperature compensation circuit.

Centre-Zero Galvanometers (1)

MeterScalesPointer at restShows
Galvanometers30–0–30 and 50–0–50Centre of the scaleSize and direction of the current

High Voltage Test Rating (1)

ListingTest voltageTest timeInsulation
High Voltage Test2000 V ACOne minuteOver 20 megohms

This listing is a rating, not a separate instrument. Name the meter you need when you order.

How to Choose Switchboard Panel Meters

  • Current or voltage. Choose an ammeter to read the current through a load and a voltmeter to read the voltage across it. The DC listing gives both types in matching cases.
  • Pick the full-scale value. Choose a range a little above the highest value you expect, so the normal reading sits in the upper half of the scale. The ammeters run from 0–1 mA to 30 A and the voltmeters from 0–20 mV to 500 V.
  • Small signals or mains-level panels. Millivolt and milliampere ranges suit electronics benches and small signals. Ampere and higher volt ranges suit motors, heaters, battery charging and supply panels.
  • Case and cut-out size. The DC meters come in 85 mm round, 100 mm round or 110 x 90 mm flush cases. Match the case to the cut-out in your panel.
  • Current that changes direction. Where the current can flow either way, as in charge and discharge circuits, a centre-zero galvanometer shows the direction at once.
  • AC or DC. The moving-coil meters read DC. State AC or DC for each ammeter and voltmeter on your order.

Tasks Covered by Switchboard Panel Meters

TaskMeter
Reading the current through a load, wired in seriesAmmeters; DC Ammeters and Voltmeters
Reading the voltage across a supply or component, wired in parallelVoltmeters; DC Ammeters and Voltmeters
Monitoring the DC output of power supplies, control panels and training boardsDC Ammeters and Voltmeters
Reading small signals such as thermocouple outputs on millivolt rangesVoltmeters
Showing the direction of current, as in battery charge and dischargeGalvanometers
Withstand and insulation rating of the panel meters: 2000 V AC for one minute, over 20 megohmsHigh Voltage Test

Who Uses Switchboard Panel Meters?

Panel builders, electrical and electronics labs, polytechnics and ITIs fit these meters into switchboards, power supply panels and training boards. Physics labs use the galvanometers where current reverses.

Ordering, Minimum Quantity and Dispatch

PointDetail
Minimum order quantity10 units of each meter, as shown on its product page
Pack quantityEach meter is sold individually
Dispatch timeUsually 7–10 working days
How to enquireUse Add To Cart on a product page, or send each range, AC or DC, the case size and the quantity through the contact page
Tenders and OEM supplySend the schedule through the tender enquiry page
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Related Ranges in Scientific Instruments

Switchboard Panel, Ammeters, Voltmeters, Rectifier Type is one of 22 subcategories of the Scientific Instrument range. These neighbouring ranges hold the bench meters and the circuits the panel meters read.

RangeHow it relates
Electrical Measuring InstrumentsBench instruments: a portable moving-coil meter, D'Arsonval, ballistic and spot galvanometers, ohms meters and insulation testers.
Digital Measuring InstrumentsDigital meters such as an AC millivoltmeter, frequency meters, an LCR meter and a millivolt and milliamp source.
Test and Measuring InstrumentsClamp on meter, vacuum tube voltmeter, Q meter and oscillators for electronics testing.
Power Supplies and TransformersBench, dual, fixed IC and valve supplies, battery chargers and battery eliminators whose outputs the meters read.
Decade BoxResistance boxes, standard resistances and rheostats used as shunts, loads and references.
Verification of Various Laws and Conservation of SignalOhm's law apparatus and the conversion of a galvanometer into a voltmeter and current meter.

Frequently Asked Questions

Why is an ammeter wired in series and a voltmeter in parallel?
An ammeter must carry the same current as the load, so it goes in series and has a very low resistance. A voltmeter reads the potential difference across a part, so it goes in parallel and draws very little current.

What happens if an ammeter is connected across the supply?
Its low resistance acts almost as a short circuit. A large current flows through the coil, which can burn it out or bend the pointer. Always switch off and check that the ammeter is in series before switching on again.

How do I choose the full-scale range of a panel meter?
Pick a range a little above the highest value the circuit should reach, so the normal reading falls in the upper part of the scale. A range that is far too large gives a small, hard-to-read deflection, and one that is too small risks damage.

Can a moving-coil meter read AC?
Not on its own. A moving-coil movement responds to direct current, and on AC the pointer only vibrates near zero. AC panels use a rectifier-type or moving-iron meter, so state AC or DC for every meter you order.

How is a meter range extended with a shunt or series resistance?
A low-value shunt in parallel with the coil carries most of the current and turns a sensitive meter into a higher-range ammeter. A high resistance in series turns it into a voltmeter. Class 12 physics uses this to convert a galvanometer.

What does a centre-zero galvanometer show that an ordinary meter does not?
The pointer rests in the middle, so it swings left for current one way and right for the other. It shows the direction of the current as well as its size, which helps in charge and discharge circuits and null checks.

Request a Quote

Name each meter, its full-scale range, AC or DC, the case size and the quantity, for example ten DC Ammeters and Voltmeters in the 100 mm round case. Then send the request from the contact page.

Ammeters

Ammeters

Product Code : EL-SPAVRT-1223

0-1A to 30 Amp.

View Details
DC Ammeters and Voltmeters

DC Ammeters and Voltmeters

Product Code : EL-SPAVRT-1224

DC Ammeters and Voltmeter

View Details
Galvanometers

Galvanometers

Product Code : EL-SPAVRT-1225

30-0-30 and 50-0-50

View Details
High Voltage Test

High Voltage Test

Product Code : EL-SPAVRT-1226

All instruments stand 2000 Volts AC for one minute and have an insulation of over 20 Meg ohms.

View Details
Voltmeters

Voltmeters

Product Code : EL-SPAVRT-1227

0-1V to 500V

View Details

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us