• +91-85699-09696

Simple Key Manufacturer,Supplier and Exporter in India

Simple Key

Product Code : EL-SK-2401
Jlab Export is a leading Simple Key Manufacturer,and suppliers in India

Closing a simple key completes an electric circuit, and opening it breaks the circuit again. In physiology practicals it sits in the primary circuit of an induction coil. Each make and each break of the cell current then gives one induced shock for stimulating a nerve or muscle. This key is mounted on a vulcanite base.

Specifications

BaseVulcanite
Key typeSimple make-and-break key
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Make and Break Shock Experiments

Students wire the key in series with a cell, such as the Leclanche Cell (Standard Size), and the primary coil of the Student Induction Coil. Leads from the secondary go to a Simple Electrode on the nerve or muscle. Closing the key gives a make shock, opening it gives a break shock, and each twitch is written on a kymograph.

A standard exercise compares the two shocks. The secondary coil starts far from the primary and is moved closer step by step, and the muscle answers the break shock first. Teachers use the result to explain self-induction in the primary coil.

Frequently Asked Questions

Why is there a shock only at make and at break?
An induction coil gives a shock only when the primary current changes. While the key stays closed the current is steady, so the secondary gives nothing until the key is opened again.

Why is the break shock stronger than the make shock?
At make, self-induction in the primary slows the rise of current. At break, the current stops almost at once, so the induced voltage in the secondary is higher and the tissue responds at a weaker coil setting.

Can a plug key or tapping key be used instead?
Yes, any make-and-break key works in the primary circuit. A Tapping Key springs open when released, which suits single shocks. A Plug Key stays closed until its plug is pulled out.

Do I also need a Du Bois-Reymond key?
For clean single shocks, yes. This key controls the primary circuit, while the Du Bois-Reymond Key short-circuits the secondary. With both, students can block the make shock and pass only the break shock.

Other Keys and Stimulation Apparatus

For a quote, use Add To Cart or send us a message through the contact page.