• +91-85699-09696

Subcool/Superheat Calculator Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-M-12788
Jlab Export is a leading Subcool/Superheat Calculator Manufacturer,and suppliers in India

Subcool/Superheat Calculator (code EL-M-12788) is an HVAC tool that works out superheat and subcooling for 37 refrigerants, from R22 and R134a to R410A and R290, and shows bubble, saturated and dew point temperatures. Pressure appears in kg/cm², MPa, bar or PSI, up to 600 PSI, and temperature in °F or °C. Each calculator is produced by JLab in Ambala, India.

Specifications

ParameterDetail
Refrigerants (37)R22, R32, R114, R123, R124, R134, R134a, R141B, R142B, R290, R401A, R401B, R404A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R411A, R411B, R414A, R414B, R417A, R421A, R422A, R422B, R422C, R422D, R427A, R434A, R437A, R438A, R441A, R507A
Temperatures shownBubble, saturated and dew point
Temperature units°F or °C
Pressure unitskg/cm², MPa, bar, PSI
Pressure display0–600 PSI
Quality checkEach calculator is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity5 units
Dispatch timeUsually 7–10 working days
Product codeEL-M-12788
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Superheat and Subcooling

Superheat is the suction line temperature minus the saturation temperature at the suction pressure; it shows how far the vapour leaving the evaporator is above its boiling point. Subcooling is the saturation temperature at the liquid line pressure minus the liquid line temperature; it shows how far the liquid leaving the condenser is below its condensing point. The calculator supplies the saturation temperature for the chosen refrigerant.

Bubble and Dew Points for Blends

A single-component refrigerant such as R22 or R134a boils at one temperature for a given pressure. Zeotropic blends such as R407C have a temperature glide: the bubble point, where the liquid starts to boil, sits below the dew point, where the last liquid turns to vapour. For these blends superheat is worked from the dew point and subcooling from the bubble point, which is why both are displayed.

Other HVAC Tools: A/C Analyser, P/T Gauge and IR Thermometer

HVAC tools are grouped in Miscellaneous under Test and Measurement Equipment.