Wireless Vacuum Gauge And P/T Gauge Combination (code EL-M-12791) is a refrigeration service instrument that pairs a micron vacuum sensor with two pressure transducers and two thermistor temperature sensors, all reporting wirelessly to a mobile app. It reads evacuation vacuum to 1 micron and refrigerant pressure up to 700 psia. This vacuum and P/T gauge set is built by JLab in Ambala, India.

Specifications

ParameterDetail
Pressure channelsTwo pressure transducers, working range 0–700 psia (48.3 bar)
Proof / burst pressure1000 psia without internal damage / 1500 psia without loss of seal
Pressure resolution0.1 psi, 0.1 bar, 1 kPa, 0.001 MPa, 0.01 kg/cm²
Pressure accuracy0.5% of full scale at 25 °C; 1% of full scale from 55 to 130 °F; 2% of full scale from −40 to 248 °F
Temperature channelsTwo NTC thermistor sensors, −40 to 130 °C (−40 to 266 °F); cord up to 80 °C, clamp up to 95 °C
Temperature resolution / accuracy0.1 °F or °C / ±0.2 °C (±0.36 °F)
Vacuum reading1 micron resolution; instant warm-up and response
Vacuum sensorCord about 33 in; magnet with 8 lb holding force; operates at 10–122 °F
Wireless range70–90 ft (Class 1) or 30–40 ft
Battery and conditionsRechargeable LiPo, 10+ hours continuous; works at −20 to 71 °C and 0–95% RH (non-condensing)
Quality checkEach gauge set is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity5 units
Dispatch timeUsually 7–10 working days
Product codeEL-M-12791
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

How Vacuum, Pressure and Saturation Readings Fit Together

While a system is being evacuated, the vacuum sensor shows the pressure left in it in microns, so the technician can see how far down the pump has pulled it. On a charged system each transducer reads refrigerant pressure, and the app takes the saturation temperature for that pressure from its refrigerant database, which can be updated. Set against the line temperature from a thermistor clamp, this gives superheat and subcool, which the app works out automatically.

Zeroing, Elevation and Logging

Pressure zeroing is a single button press at the start of each session, and entering the elevation then lets the gauge correct its psia readings. The highest and lowest pressures are displayed and recorded. The app logs values while the job is in progress, reconnects if the signal is lost and lets the logged data be downloaded for graphing in a spreadsheet.

Other Refrigeration Diagnostic Instruments

Further service instruments are grouped under Miscellaneous within Test and Measurement Equipment.