A heated bath circulator warms a bath of liquid and pumps it. The flow keeps the bath even for samples immersed in it, or it travels out through tubing to an instrument and back. This unit controls temperatures above ambient, has a built-in circulator pump and is compact enough to stand under or on a work bench.

Specifications

Working rangeAbove ambient
PumpBuilt-in circulator pump
ApplicationsExternal instruments and immersion work
PlacementUnder or on the work bench
NoiseLow
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Physical Chemistry Practicals with External Loops

Refractive index changes with temperature, so readings on an ABBE Refractometer are taken with warm water circulating round the prisms from the bath. Students then measure a series of sugar or glycerol solutions at one steady temperature and plot index against concentration.

For reaction kinetics, flasks of an ester and acid sit in the bath itself. Samples are withdrawn at timed intervals and titrated against alkali from a Burette, Borosilicate Glass, with PTFE Stopcock to follow the rate of hydrolysis.

Frequently Asked Questions

What tubing should connect the circulator to an instrument?
Use heat-resistant tubing of the right bore, kept as short as the layout allows, and secure every connection with a clamp. Short or insulated tubing loses less heat on the way to the instrument.

Can the circulator cool below room temperature?
No. It heats only, so it works above ambient. For work below room temperature, a refrigerated unit such as the Refrigerated Circulating Liquid Bath is needed.

Why does the bath level drop after I connect a loop?
When the pump starts, liquid fills the tubing and the jacket of the instrument. Top up the bath once the loop is full, so the heater and pump stay well covered.

How do I keep the instrument at the set temperature?
Some heat is lost in the tubing, so check the temperature at the instrument, not only in the bath. If it reads low, raise the bath setting slightly or shorten and insulate the tubes.