• +91-85699-09696

Refrigerated Circulating Liquid Bath Manufacturer,Supplier and Exporter in India

Refrigerated Circulating Liquid Bath

Product Code : EL-WB-3948
Jlab Export is a leading Refrigerated Circulating Liquid Bath Manufacturer,and suppliers in India

This bath both chills and heats a liquid and pumps it out to equipment that needs a steady temperature. Typical loads are a rotary evaporator condenser, a refractometer or a jacketed chromatography column. Its inner chamber and lid are stainless steel and the outer body is powder-coated CRC sheet. PUF insulation fills the space between them.

Specifications

FunctionRefrigerated and heating circulator
PumpBuilt-in circulator pump
Inner chamber and lidStainless steel
Outer bodyCRC sheet, powder coated
InsulationPUF between inner and outer chamber
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Experiments with Cooled External Systems

Low-boiling solvents escape a warm condenser, so the Rotary Vacuum Evaporator recovers far more solvent when cold liquid from this bath runs through its coil. Students can compare how much solvent collects in the receiver with tap-water cooling and with the bath.

Optical rotation of a sugar solution changes slightly with temperature. Students feed a jacketed sample tube from the bath, hold it at chosen settings and record the angle at each on a Research Polarimeter. In biotechnology labs, the same bath can cool the buffer of a Horizontal Electrophoresis System during long runs.

Frequently Asked Questions

How do I connect it to a rotary evaporator condenser?
Run tubing from the bath outlet to the lower connection of the condenser and return it from the upper one, so the coil fills completely. Clamp both hoses and check for leaks before starting the pump.

Why stainless steel inside and PUF insulation?
Stainless steel does not rust in water or in water and coolant mixtures. The PUF layer cuts the heat that leaks in from the room, so the refrigeration unit works less to hold a low setting.

How long does it take to reach a low setting?
That depends on the volume in the bath, the setting, the room temperature and the heat coming back from the external loop. Start it well before the experiment and keep the lid closed while it cools.

What reduces the cooling at the instrument?
Long or uninsulated tubing, a warm room and tight or kinked tubes all cut the cooling that reaches the instrument. Keep the tubing short, insulate it for low settings and avoid sharp bends.

Other Circulators and Cooling Baths

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   