Humidifier Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12811
Jlab Export is a leading Humidifier Manufacturer,and suppliers in India
This humidifier puts water vapour back into the air of a room or lab that has become too dry. It runs on 220-240 V at 50 Hz and has a capacity of 0.8 litres of water per hour. Ordinary tap water is all it needs, and an internal light shows when it is working.
Specifications
| Power supply | 220–240 V, 50 Hz |
| Capacity | 0.8 l/h |
| Water | Ordinary tap water |
| Indicator | Internal light when in use |
| Purpose | Relieves a dry atmosphere |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Humidity Experiments for Students and Teachers
Students can record the relative humidity of a closed room before the humidifier is switched on and then every few minutes while it runs. A Digital Psychrometer shows dry bulb, wet bulb and dew point together, so each reading can be plotted on a psychrometric chart. A Temperature and Humidity Data Logger left in the room keeps a record of the whole run for later work.
A simple mass balance follows. Students note the water used in one hour, work out the rise in moisture content of the room air from their chart readings, and compare the two. In an air conditioning course this leads on to the Air Washer Test Rig, where air is humidified or dehumidified with water sprays.
Frequently Asked Questions
What water does this humidifier need?
Plain tap water, with no distilled water or additives. Hard water leaves mineral scale over time, so empty the tank when the unit stands unused and descale it now and then.
How much moisture does it add to the air?
Its capacity is 0.8 l/h of water. The rise in room humidity depends on the room volume, the air change rate and how dry the air was at the start. Check the result with a hygrometer.
What humidity should a room or lab be kept at?
Aim for the middle of the humidity scale. Very dry air causes discomfort and static, while air kept too moist leads to condensation on windows and walls. Switch the unit off once a hygrometer shows the level you want.
How often should the water be changed?
Empty the tank and refill it with fresh tap water each day the unit runs, rather than topping up old water. Standing water lets mould and bacteria grow, and they can be carried into the room with the moisture. Clean the tank as its instructions say, and dry every part before storage.
What does the light on the unit show?
The internal light comes on while the humidifier is in use, so you can see from across the room that it is switched on and working.
Other Humidity Instruments and Test Rigs
- Digital Thermometer/Hygrometer
- Airflow + Psychrometer
- Psychrometer (wet and dry bulb type)
- Air Conditioning Test Rig (humidification and dehumidification studies)
For a quote, use Add To Cart or send us a message through the contact page.