Pressure To Current Measurement Trainer Manufacturer,Supplier and Exporter in India
Product Code : EL-MLLE-9170
Jlab Export is a leading Pressure To Current Measurement Trainer Manufacturer,and suppliers in India
This trainer shows the pressure to current conversion that a pressure transmitter performs. A foot air pump builds pressure in a chamber fitted on a base board, and the chamber carries a pressure transducer and a Bourdon pressure gauge. A digital indicator displays the pressure sensed by the transducer, and the 4–20 mA transmitter output is read on a current meter.
Specifications
| Pressure source | Foot air pump |
| Pressure chamber | Fitted on a base board |
| Fitted to the chamber | Pressure transducer and Bourdon pressure gauge |
| Display | Digital pressure indicator with transmitter output |
| Transmitter output | 4–20 mA, read on a current meter |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Transmitter Calibration Exercises for Students
Students raise the chamber pressure in steps with the foot pump. At each step they note the Bourdon gauge, the digital indicator and the output current. A plot of current against pressure should be a straight line, from 4 mA at the lowest range value to 20 mA at the top. A second run at the same points shows repeatability, and the gap between gauge and indicator shows how closely the two agree.
Students can see how a Bourdon gauge is itself calibrated on the Dead Weight Pressure Gauge Tester, where known weights on a piston set the test pressure. The opposite conversion, current to air pressure, is done on the Current To Pressure Measurement Trainer. For a resistive pressure sensor read on a digital panel meter, the Pressure Measurement Kit makes a useful comparison.
Frequently Asked Questions
Why is the output 4–20 mA and not 0–20 mA?
Starting at 4 mA gives a live zero. A reading of 0 mA then points to a broken wire or a failed transmitter, not to zero pressure. The 4 mA floor also leaves enough current to power a two-wire transmitter from the loop.
How do I work out the expected current at a given pressure?
Divide the pressure by the full range of the transmitter, multiply by the 16 mA span between 4 and 20 mA, and add 4 mA. At half range, for example, the expected output is 12 mA.
Does the trainer need a compressed air line?
No. A foot air pump is supplied as the pressure source, so no compressor or air line is needed. Students press the pump to raise the chamber pressure in small steps, one step for each set of readings.
What is a Bourdon pressure gauge?
It is a dial gauge built around a curved, flattened tube. Pressure inside the tube makes it straighten slightly, and a linkage turns that movement into the pointer reading. Here it gives a mechanical reading to set against the transducer.
How does a pressure transducer differ from a transmitter?
A transducer turns pressure into a small electrical signal. A transmitter conditions that signal into a standard output, here 4–20 mA, which can run along a long cable to a controller or indicator without the reading changing.
Other Pressure Measurement and Control Equipment
- Pressure Measurement Apparatus
- Pressure Measurements
- Pressure Process Control Trainer (with a two-wire pressure transmitter)
- Water Pressure Control Trainer
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 5 November 2026
