• +91-85699-09696

PVC Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-MWLE-13071
Jlab Export is a leading PVC Manufacturer,and suppliers in India

White schedule 40 PVC pipe is the rigid plastic pipe used for cold water lines and for the condensate drains of air conditioners. This pipe is rated at 600 psi and comes in 10 ft lengths, in 1/2 in and 3/8 in sizes. Lengths are joined with PVC fittings and solvent cement.

Specifications

MaterialPVC, white
WallSchedule 40
Pressure rating600 psi
Sizes1/2 in x 10 ft, 3/8 in x 10 ft
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Condensate Drain Practicals

During split unit installation practice, trainees run a condensate drain from the indoor unit of a Split Air-Conditioner to a drain point. They cut the pipe square with a Tube Cutter made for copper and PVC, remove the burr and dry-fit every joint before cementing. The run keeps a steady fall all the way, with no sags where water could stand.

Where the drain shares the wall route with the refrigerant lines, it is laid in the Base And Cover duct beside them. Teachers finish the job by pouring water into the drain pan, and students trace the flow and check each joint for drips.

Frequently Asked Questions

What does schedule 40 mean?
Schedule is the wall thickness class of the pipe. Schedule 40 is the standard wall for general water and drain work, while schedule 80 pipe of the same size has a thicker wall for higher pressure.

Is the 600 psi rating good at any temperature?
No. PVC pressure ratings are given for cold water at room temperature, and the safe pressure falls as the water gets warmer. Use PVC for cold water and drains, never for hot water or compressed air.

Why does a 1/2 in pipe measure more than 1/2 in?
Pipe sizes are nominal. The outside diameter of schedule 40 pipe is larger than its size name, so fittings are chosen by the nominal size rather than by measuring the pipe.

How are the lengths joined?
Cut square, deburr and clean both parts, and apply PVC primer where the cement maker asks for it. Coat the pipe end and the socket with solvent cement, push the pipe fully home with a quarter turn and hold it for a few seconds.

Other Pipe and Duct Items

For a quote, use Add To Cart or send us a message through the contact page.