Temperature and Precision Control Water Bath Manufacturer,Supplier and Exporter in India
Product Code : EL-WB-3955
Jlab Export is a leading Temperature and Precision Control Water Bath Manufacturer,and suppliers in India
This water bath stirs its own water. A stainless steel rod and blade keep the tank moving, so the temperature is the same in every corner, and a solid state controller holds the setting. The stainless steel chamber measures 430 x 240 x 265 mm and works from above ambient up to 100°C.
Specifications
| Controller | Solid state |
| Stirrer | Stainless steel rod and blade |
| Chamber | Stainless steel sheet |
| Chamber size | 430 x 240 x 265 mm |
| Temperature | Above ambient to 100°C |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Physical Chemistry Practicals at Fixed Temperature
Distribution experiments need both layers at one temperature. Students shake an acid such as benzoic acid with water and an immiscible solvent in a Separating Funnel. The funnel stands in the bath until the layers settle, and then each layer is titrated. Repeating the run at a second setting shows how the partition ratio changes with temperature.
Rate experiments also use the bath. Reactant solutions warm separately in Narrow Neck Conical Flasks, Erlenmeyer, Borosilicate Glass before they are mixed. The reaction then starts at the bath temperature, not at room temperature.
Frequently Asked Questions
What does a solid state controller mean?
It is an electronic controller that switches the heater without moving contacts. It replaces the older contact thermometer or bimetal thermostat, and it has no mercury column to break or contacts to wear.
Where should vessels sit relative to the stirrer blade?
Keep flasks and tubes clear of the blade, with the blade fully under water. The stirred water then flows past every vessel, and nothing knocks against the rod while it turns.
How long should I wait before taking readings?
Let the bath reach the setting with the stirrer running, then allow time for the liquid inside your flasks to catch up. A thermometer in a flask of water beside the samples shows when they have reached temperature.
Can the bath be used near 100°C?
Yes, but water close to boiling evaporates quickly. Keep the bath covered as far as the work allows, check the level often and top up with hot water so the temperature does not drop sharply.
Other Constant Temperature Water Baths
- Water Bath Precision
- Temperature and Precision Control Water Bath (Hospital Lab)
- Circulatory Water Bath
- Water Bath Rectangular
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026
