Analog Sampling and Reconstruction Kit (code EL-PET-10210) is a communication lab training kit for the sampling theorem: an analog sine wave is sampled, then rebuilt with a low-pass filter. Both the sampling frequency and the sampling duty cycle are switch-selectable. Jain Laboratory Instruments Pvt Ltd (JLab) manufactures the kit at its Ambala works in India.

Specifications

ParameterDetail
Message signalsSynchronised sine waves of 1 kHz and 2 kHz, amplitude adjustable 0 to 5 Vp-p
Sampling frequencySwitch-selectable: 2, 4, 8, 16 or 32 kHz
External sampling inputUp to 40 kHz, amplitude 5 V
Sampling circuitsSample circuit and sample-and-hold circuit, each with an output
Sampling duty cycleSwitch-selectable, 0 to 90% in steps
Low-pass filters2nd-order and 4th-order, cut-off 3.4 kHz
Quality checkEach kit is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity10 units
Dispatch timeUsually 7–10 working days
Product codeEL-PET-10210
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

What Is the Sampling and Reconstruction Kit Used For?

The sampling theorem says a signal can be recovered from its samples if it is sampled at more than twice its highest frequency. This kit lets a communication lab test that rule: the sine is sampled, low-pass filtered and compared with the original as the settings change.

Frequently Asked Questions

Why does the sampling frequency go as low as 2 kHz?
So that under-sampling can be seen. 2 kHz is only twice the 1 kHz tone and equal to the 2 kHz tone, so at the low settings the rebuilt waveform is distorted; as the rate rises it approaches the original.

What does the duty-cycle switch change?
It sets how long each sampling pulse lasts. A wider pulse passes more of the signal, so the reconstructed output grows as the duty cycle is raised.

Why are there 2nd-order and 4th-order filters?
A higher-order filter falls off more steeply above cut-off and removes more of the sampling components, so comparing the two shows the effect of filter order.

OEM Manufacturer

JLab is how Jain Laboratory Instruments Pvt Ltd trades: an Indian manufacturer of electronics trainers and laboratory equipment, incorporated in 2017 and working from Hargolal Road, Ambala, Haryana. The kit is made in JLab’s own works, not sourced from a trader, so colleges, dealers and importers buy it factory-direct, with repeat orders and spares from the same works. JLab exports worldwide and ships to buyers in every region — for example Kazakhstan in Central Asia, Burkina Faso in West Africa, France in Western Europe, Algeria in North Africa and Ukraine in Eastern Europe.

Related Sampling and PAM Trainers

More in the Communication Trainer, Power Electronics Trainers and Electronics Lab Equipments ranges.