The Andreasen pipette finds the particle size distribution of a powder by sedimentation. A suspension of the powder settles in a 500 ml cylinder graduated from 0 to 20 cm. At set times a 10 ml sample is drawn through the pipette, whose tip sits level with the 0 mark. A three-way stopcock lets each sample be drawn and run out.

Specifications

MethodParticle size determination by sedimentation
Cylinder500 ml, graduated 0 to 20 cm
Pipette10 ml, with three-way stopcock
Pipette tipLevel with the 0 mark of the cylinder
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Particle Size Practical by Sedimentation

In pharmaceutical engineering labs, students suspend a weighed amount of a fine powder such as calcium carbonate in water with a little dispersing agent. They shake the cylinder, stand it upright and start a Stop Watch. Samples are drawn at set times into weighed dishes, dried in a Hot Air Universal Oven and weighed on an Electronic Balance.

From each sampling time and the fall height, Stokes’ law gives the size of the biggest particle still in suspension at the tip. Students plot cumulative percent undersize against diameter. Teachers often have them compare the result with a sieve analysis of the same powder on Test Sieves.

Frequently Asked Questions

How does Stokes’ law give particle size from the sampling times?
Stokes’ law links settling speed to particle diameter, liquid viscosity and the density difference between particle and liquid. Dividing the fall height by the time gives the speed, and from that the biggest diameter still in suspension at the tip depth.

When should the timing start?
Start the stopwatch the moment you stop shaking and stand the cylinder upright. Every sampling time counts from that instant, so a late start throws off every calculated size.

Why is a dispersing agent added to the suspension?
Fine particles stick together in clumps, and a clump settles like one larger particle. A little dispersing agent and thorough shaking keep them apart, so each particle settles at its own speed.

How do I avoid disturbing the suspension when sampling?
Draw each sample slowly and steadily through the stopcock, taking about the same time for every sample. Do not move or knock the cylinder between samples.

Why are the samples dried and weighed?
Each 10 ml sample holds the solid still suspended at the tip depth at that moment. Drying off the water and weighing the residue gives the fraction finer than the size calculated for that time.