Circuit Breaker (MCB, 1 Pole, 32 A) Manufacturer,Supplier and Exporter in India
Product Code : EL-BE-12868
Jlab Export is a leading Circuit Breaker (MCB, 1 Pole, 32 A) Manufacturer,and suppliers in India
A miniature circuit breaker opens a circuit by itself when the current runs too high. It also serves as the on and off switch for that circuit. This single-pole breaker is rated at 32 A for 230/400 V AC, 50 Hz supplies. It trips on the C curve and can break a short-circuit current of up to 6 kA.
Specifications
| Rated current | 32 A |
| Rated voltage | 230/400 V AC, 50 Hz |
| Poles | 1 |
| Trip characteristic | C curve |
| Short-circuit breaking capacity | 6 kA |
| Width | 1 module, 17.5 mm |
| Mounting | DIN rail |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Board Wiring Practicals for Students
In an ITI or diploma wiring lab, students clip the breaker onto a DIN rail, run the line conductor through it and feed a socket or heater circuit. An RCD Residual Current Device fitted ahead of it on the same rail shows how the duties are split. The RCD answers leakage to earth, and the breaker answers overload and short circuit.
In a motor control practical, the breaker protects the supply to a Contactors starter with its overload relay. Students then compare the two devices: the relay is set to the motor’s own current, while the breaker guards the wiring and clears a short circuit at once.
Frequently Asked Questions
Is 32 A the right rating for our circuit?
Add up the current of every load the circuit will carry, then check the cable. The rating must sit above the normal load current but never above what the cable can carry. This breaker therefore needs cable sized for at least 32 A.
Do we need a single-pole or a multi-pole breaker?
A single-pole breaker opens only the line conductor of a single-phase circuit, which suits most sockets, lamps and heaters on a trainer bench. Three-phase loads need a three-pole breaker so that all phases trip together.
Does a hot panel change when the breaker trips?
Yes. The overload trip uses a bimetal strip that bends with heat, so in a warm enclosure it reaches its trip point at a lower current. Leave space round heavily loaded breakers, keep the panel ventilated, and allow for derating if the board runs hot.
Why does it trip slowly on an overload but at once on a short circuit?
It has two trips. On a moderate overload the bimetal strip warms and bends over seconds or minutes, which lets brief switch-on surges pass. A short circuit draws a very large current, and a magnetic coil then pulls the latch open almost instantly.
Why use an MCB instead of a rewirable fuse on a lab bench?
A blown fuse must be rewired or replaced, and the wrong fuse wire can be fitted by mistake. The breaker is switched back on once the fault is cleared. Its trip point cannot be altered by the user, and the handle shows whether it has tripped.
What should students do before switching a tripped breaker back on?
Find out why it tripped. Switch off or unplug the loads, look for a damaged lead or a short, and only then reset it. If it trips again at once with every load off, the fault is in the wiring and must be traced first.
Other Circuit Breakers in the Range
- Circuit Breaker (10 A, single pole)
- Circuit Breakers (16 A, single pole)
- Circuit Breaker (25 A, single pole)
- Circuit Breaker (16 A, three pole)
For a quote, use Add To Cart or send us a message through the contact page.