Cross Flow Heat Exchanger (code EL-HTTLP-9223) is a small-scale exchanger in which water and an air stream driven by an axial fan cross each other at right angles, for teaching the fundamentals of heat transfer. A separate service unit, supplied by JLab with fittings matched to this cross-flow model, provides the water flow and the readings. K-type thermocouples measure the water and air temperatures at inlet and outlet. JLab builds the cross-flow unit in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Flow arrangement | Cross flow, water and air |
| Air side | Axial fan; air mass flow rate derived from an air velocity sensor |
| Temperature sensors | K-type thermocouples at the water and air inlets and outlets |
| Mounting | PVC base plate, installed without tools on the plinth of its matching service unit |
| Service unit | Supplied separately: water reservoir, pump, temperature and flow readings, couplings matched to this cross-flow exchanger |
| Cleaning | Probes and axial fan remove easily |
| Supplied with | Instruction manual |
| Quality check | Each cross-flow exchanger is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-HTTLP-9223 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Analysing a Cross-Flow Exchanger
Because the two streams cross at right angles, the temperature difference between them changes across the core as well as along it, so the plain counter-flow LMTD cannot be used as it stands. It is multiplied by a correction factor F, at most 1, read from cross-flow charts for the measured temperatures; alternatively the effectiveness–NTU method is used, where effectiveness is the heat transferred divided by C_min × (hot inlet − cold inlet).
The air mass flow is the measured velocity × the flow area × the air density, and with the change in air temperature it gives the heat exchanged on the air side; the water flow rate and its temperature change give the matching figure on the water side. The parameters of the cross-flow exchange can be varied from run to run for a complete analysis, and the probes and axial fan come off easily for cleaning.
Other Tubular, Concentric and Plate Exchangers
- Tubular Heat Exchanger — clear acrylic and stainless steel concentric tubes, run from a heat exchanger service unit.
- Parallel and Counter Flow Heat Exchanger — water-to-water concentric unit with rotameters and a heated recirculating tank.
- Concentric Tube Heat Exchanger — also offered as a finned-tube water-to-air version.
- Plate Type Heat Exchanger Apparatus — hot and cold water passing between alternate stainless steel plates.
Heat Transfer Through Lagged Pipe is the category for this exchanger, inside Heat Transfer Lab Equipment.