Heat Transfer Through Lagged Pipe (code EL-HTTLP-7369) is a heat transfer lab set-up for measuring the thermal conductivity of pipe lagging from the heat that flows radially out through it, specified with a G.I. pipe of 25 mm diameter and 1000 mm length and a capacity of 5 kW. JLab builds each lagged pipe set-up in Ambala, India, in the different specifications buyers ask for.
Specifications
| Parameter | Detail |
|---|---|
| Capacity | 5 kW |
| Material | G.I. (galvanised iron) |
| Diameter | 25 mm |
| Length | 1000 mm |
| Options | Available in different specifications |
| Quality check | Each lagged pipe set-up is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-HTTLP-7369 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Radial Conduction Through the Lagging
Heat leaving the pipe crosses the lagging along the radius, so the area it passes through grows with distance from the centre. For a lagging layer with inner radius r1, outer radius r2 and length L, the conduction resistance is ln(r2/r1)/(2πkL), and at steady state the heat flow is Q = 2πkL(T1 − T2)/ln(r2/r1), where T1 and T2 are the temperatures at the inner and outer surfaces of the lagging. With Q and the two surface temperatures known, the same relation is solved for the thermal conductivity k.
Because the resistance depends on ln(r2/r1) rather than on the thickness alone, doubling the lagging thickness does not halve the heat loss. That is where a lagged pipe parts company with a flat wall, in which each layer adds a resistance of thickness/(kA).
Other Conduction Rigs: Pipe, Wall and Spheres
- Lagged Pipe Apparatus — three concentric G.I. pipes with two lagging materials and a cartridge heater.
- Heat Transfer Through Composite Wall — conduction through a composite wall of MS, Bakelite and wood specimens.
- Thermal Conductivity of Insulating Powder — radial conduction through powder held between two concentric copper spheres.
The set-up belongs to the Heat Transfer Through Lagged Pipe category of Heat Transfer Lab Equipment, part of the Engineering Lab Equipment range.
Request a Quote
Order through Add To Cart, or send the specification you want, the number of set-ups and the delivery town through the contact page.
Last updated: 30 October 2026