Darwin Potometer Manufacturer,Supplier and Exporter in India
Product Code : EL-RE-5122
Jlab Export is a leading Darwin Potometer Manufacturer,and suppliers in India
Water uptake by a cut leafy shoot is measured with this Darwin potometer. Once the apparatus is filled with water, an air bubble moves along the capillary as the shoot draws water in. The glass tube has a rubber stopper closing the upper end of its straight limb, and a bored stopper at the lower end takes a length of capillary tubing.
Specifications
| Body | Glass tube |
| Upper end of straight limb | Closed with a rubber stopper |
| Lower end of limb | Bored rubber stopper that takes a length of capillary tubing |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Transpiration Practicals with the Potometer
Students cut a leafy shoot under water, so that no air enters the xylem, fit it into the filled potometer and seal every joint. With the open end of the capillary dipping into a Beaker of water, they lift it out for a moment to let in one air bubble. They then time the bubble over a measured distance with a Stop Watch.
Repeating the reading in still air, in front of a fan, in bright light and with the shoot inside a polythene bag shows how wind, light and humidity change the rate. Teachers use the results to explain that the apparatus measures water uptake. Transpiration accounts for most of that water, so the two rates are close but not equal.
Frequently Asked Questions
Why must the leaves be dry before timing starts?
The leaves often get wet while the shoot is cut and fitted under water. A film of water keeps the air at the leaf surface damp and covers the stomata, so less vapour escapes and the bubble slows. Blot the leaves gently and let them dry before the first reading.
How can results from two shoots be compared?
Shoots differ in leaf area, so raw bubble rates cannot be set side by side. Trace the leaves on squared paper to find their total area, then divide the rate of uptake by that area. Rates per unit of leaf area can be compared between shoots or species.
How is the rate of water uptake worked out?
Divide the distance the bubble moves by the time taken, for example in mm per minute. If the bore of the capillary is known, multiply the distance by the area of the bore to give the volume of water taken up.
Why must every joint be airtight?
A leak lets air in or water out, and the bubble then moves for reasons that have nothing to do with the shoot. Smear petroleum jelly round the stoppers and the stem, and keep the apparatus clamped upright while readings are taken.
Why should the shoot settle before readings start?
A freshly fitted shoot needs a few minutes to adjust to the light and air around it. Start timing only when the bubble moves at a steady rate, then take three readings for each condition and work out the mean.
Other Potometers