• +91-85699-09696

Motorised Casagrande Equipment Manufacturer,Supplier and Exporter in India

Motorised Casagrande Equipment

Product Code : EL-SM-8864
Jlab Export is a leading Motorised Casagrande Equipment Manufacturer,and suppliers in India

A geared motor turns the cam on this liquid limit device, so the cup rises and falls at an even pace while a mechanical counter records each drop. The spun brass cup sits on a pin and slot mounting above a molded hard rubber base. It runs on 220 V AC, 50 Hz.

Specifications

UseLiquid limit of soil
DriveGear motor on the metal base, enclosed in the housing, with on-off switch
CounterMechanical, records the number of cup drops
CupSpun brass, pin and slot mounting
BaseMolded hard rubber
CamMolded self-lubricating plastic
HousingAluminium, holds the cup and the drop adjustment parts
Power220 V AC, 50 Hz
Supplied withGrooving tools
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Liquid Limit Practicals with a Motor Drive

With the motor setting the drop rate, students can watch the groove instead of counting turns. A class mixes soil with water, spreads it in the cup and cuts a groove with the grooving tool. The motor is stopped as soon as the groove closes, and the counter gives the drops. Several trials from wet to dry are run, and a small sample from each is dried in the Laboratory Bench Oven.

The flow curve of water content against the number of drops, on a log scale, gives the liquid limit at the standard drop count. With the plastic limit from the Plastic Limit Roller, students work out the plasticity index and place the soil on a plasticity chart. The Shrinkage Limit Set completes the consistency limits for the same soil.

Frequently Asked Questions

Why choose a motorised liquid limit device over a hand one?
The test is the same. The motor keeps the drop rate even from trial to trial and from one operator to the next, and the counter does the counting. That removes two common causes of scatter in student results.

When should I stop the motor in each trial?
Watch the groove, not the counter. Switch off at the on-off switch as soon as the soil from both sides flows together along the base of the groove. Note the counter reading before each trial, so the drops are the difference between the two readings.

Does the cam need oiling?
No. The cam is molded from self-lubricating plastic. Keep soil off the cam and the cup mounting, and wash the cup after each test. Look at the rubber base for dents or wear, since a worn base changes the blow count.

Can the cup be taken off for cleaning?
The cup is held by a pin and slot mounting, so it can be lifted off, washed and refitted. Dry it before the next trial so that no extra water reaches the soil.

What should I check before the first trial?
Plug it into a 220 V AC, 50 Hz supply, then run a few drops with the cup empty using the on-off switch. Check that the counter advances once per drop and that the cup lands squarely on the base.

More Soil Classification Test Equipment

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 6 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us