Photosynthesis and Respiration Chamber

Product Code : EL-BE-9660
Jlab Export is a leading Photosynthesis and Respiration Chamber Manufacturer,and suppliers in India

A plant sealed in a clear bottle takes in carbon dioxide and gives off oxygen in the light, then reverses the exchange in the dark. This chamber lets a class follow that cycle with data-logging oxygen, carbon dioxide and light sensors. It comes as a one-gallon clear glass bottle with a cap and rubber stoppers. Sensors and plants are not part of the kit.

Specifications

ChamberClear glass bottle with cap, 1 gallon (about 3.8 litres)
StoppersRubber stopper size 00 and rubber stoppers size 7
For use withData-logging oxygen (O2), carbon dioxide (CO2) and light sensors
PlantsNot included
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Experiments with the Chamber

Students place a small potted plant in the bottle and seal it with the sensors in place. They then record under a lamp. Carbon dioxide falls and oxygen rises while photosynthesis runs faster than respiration. Covering the bottle with foil reverses both curves and shows respiration on its own.

A Light Sensor beside the bottle shows how bright the lamp is, so groups can repeat the run at several lamp distances and plot rate against light. The Datalogger, whose basic unit includes a luminosity sensor, can log light levels for the whole class. A simpler version needs no sensors. A Bell Jar (Plant Physiology) over a plant kept in the dark, with a dish of Lime Water beside it, shows carbon dioxide from respiration.

Frequently Asked Questions

What must be ordered alongside the chamber?
The kit holds the bottle, cap and rubber stoppers. Each group also needs data-logging oxygen, carbon dioxide and light sensors with a logger or computer, a small potted plant and a lamp. Aluminium foil or a dark box is handy for the dark runs.

Why do readings drift at the start of a run?
Gas sensors need a few minutes to warm up, and the air in a freshly sealed bottle takes time to mix. Start logging, but take the rate only from the steady part of the curve. Opening the bottle between runs lets the air return to room levels.

Why does mist form inside the bottle, and does it matter?
The plant gives off water vapour, and in a sealed bottle it condenses on the glass. A little mist is normal. Keep the lamp from warming the bottle, wipe the glass dry between runs, and keep drops away from the sensor tips.

How far should the lamp be from the bottle?
Far enough that the glass stays cool to the touch. A lamp that is too close warms the air, which upsets the readings and can stress the plant. Some groups set a clear tray of water between lamp and bottle to absorb heat, then move the lamp to vary the light.

How is the rate worked out from the graph?
Fit a straight line to a steady stretch of each curve. The slope gives the change in gas concentration per minute. A falling carbon dioxide line in the light shows net photosynthesis, and a rising line in the dark shows respiration. Compare slopes, not single readings.