Gear Pump Test Setup Manufacturer,Supplier and Exporter in India
Product Code : EL-HM-10036
Jlab Export is a leading Gear Pump Test Setup Manufacturer,and suppliers in India
Gear Pump Test Setup (code EL-HM-10036) is a closed-loop oil bench on which a 1 HP gear pump with a pair of meshed gears is tested at up to 1500 rpm and 5 kg/cm² head. Students read delivery pressure and suction vacuum on the gauges and time the oil into a measuring tank with piezometer tube on the electronic stopwatch, which gives all the data for efficiency and head–discharge curves. Every gear pump setup is built by JLab in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Pump | Gear pump, pair of meshed gears, 1 HP |
| Speed / head | 1500 rpm (max.); 5 kg/cm² (max.) |
| Drive options | AC motor with step cone pulley for 3 preset speeds; DC motor with DC drive and non-contact digital rpm indicator |
| Supply tank | 30 litres |
| Measuring tank | 20 litres, with piezometer tube and scale |
| Circulating fluid | Oil; 30 litre oil charge optional |
| Tanks and wetted parts | Stainless steel |
| Piping | GI / PVC |
| Stopwatch | Electronic |
| Electric supply | 230 ± 10 V AC, 50 Hz, single phase, earthed; 5 A three-pin socket |
| Quality check | Each pump test setup is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-HM-10036 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Positive Displacement in a Gear Pump
As the gears turn, oil trapped in the tooth spaces is carried round the casing from suction to delivery, and the meshing teeth stop it returning. Each revolution therefore moves a nearly fixed volume, so discharge depends mainly on speed rather than on head; only internal leakage, which grows with pressure, makes it fall slightly as head rises. Changing speed with the step cone pulley or the DC drive is the main way to change flow.
Readings and Results
Delivery pressure and suction vacuum give total head, and the volume of oil collected in the measuring tank over a stopwatch interval gives actual discharge. From these, pump output power ρgQH, pump efficiency and overall efficiency are worked out, and head and pump efficiency are plotted against discharge. Comparing actual discharge with the displacement per revolution times speed gives the volumetric efficiency, and a spreadsheet sample calculation program is available on demand.
Other Pump Test Rigs to Compare
- Gear Oil Pump Test Rig — gear pump rig with DC drive and digital rpm indicator.
- Reciprocating Pump Test Setup — double-acting piston pump, another positive displacement design.
- Submersible Pump Test Rig — submersible pump performance study with delivery and suction gauges.
It sits with the other pump and turbine rigs in Hydraulic Machine, part of Fluid Mechanics and Hydraulics Lab Equipment.
Request a Quote
Tell us the drive option, the quantity and the delivery address through Add To Cart or the contact page to receive a quotation.
Last updated: 30 October 2026