Reciprocating Pump Test Setup (code EL-HM-10035) is a compact, stand-alone rig for testing a 1 HP double-acting, single-cylinder reciprocating pump in a closed water loop, at up to 250 rpm and 5 kg/cm² head. Pressure and vacuum gauges on delivery and suction, with a measuring tank and electronic stopwatch, give the readings for efficiency and head–discharge curves. JLab produces this pump test setup in Ambala, India.

Specifications

ParameterDetail
PumpDouble acting, single cylinder, 1 HP
Speed / head250 rpm (max.); 5 kg/cm² (max.)
Drive optionsAC motor with step cone pulley for 3 preset speeds, or DC motor with DC drive and non-contact digital rpm indicator
Supply tank70 litres
Measuring tank50 litres, with piezometer tube and scale
Tanks and wetted partsStainless steel
PipingGI / PVC
StopwatchElectronic
Electric supply230 ± 10 V AC, 50 Hz, single phase, earthed; 5 A three-pin socket
WaterTap connection, ½ inch BSP; 80 litres distilled water optional
Quality checkEach pump test setup is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-HM-10035
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Slip and Coefficient of Discharge

A double-acting cylinder delivers on both strokes, so theoretical discharge is 2ALN, where A is the piston area, L the stroke length and N the speed in revolutions per second, ignoring the piston rod. Actual discharge comes from the rise in the measuring tank over a stopwatch interval. Their ratio is the coefficient of discharge Cd, and slip, the share of theoretical flow lost through valve lag and leakage, equals 1 − Cd. Changing speed on the drive shows how slip varies.

Efficiency and Performance Curves

Total head is taken from the delivery pressure and suction vacuum readings, and pump output power is ρgQH. Dividing this by shaft power gives pump efficiency, and dividing by electrical input gives overall efficiency. Head and pump efficiency are plotted against discharge, and a spreadsheet sample calculation program can be supplied on demand.

Other Pump Test Rigs and Setups

Find related rigs in Hydraulic Machine, under Fluid Mechanics and Hydraulics Lab Equipment.

Request a Quote

Choose the AC or DC drive and send it, with the quantity and delivery town, through Add To Cart or the contact page.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us