High Temperature Oil Bath Manufacturer,Supplier and Exporter in India
Product Code : EL-WB-3958
Jlab Export is a leading High Temperature Oil Bath Manufacturer,and suppliers in India
This bath heats oil up to 150°C under thermostatic control, for flasks that must run hotter than boiling water allows. A high speed stirrer with its own speed controller keeps the oil moving. The chamber is copper or stainless steel sheet and comes in three sizes, from 250 x 250 x 250 mm to 355 x 355 x 250 mm.
Specifications
| Chamber material | Copper or stainless steel sheet |
| Temperature control | Thermostatic, up to 150°C |
| Stirrer | High speed, with speed controller |
| Chamber sizes | 250 x 250 x 250 mm, 300 x 300 x 250 mm, 355 x 355 x 250 mm |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
High Temperature Experiments in the Oil Bath
Physics students use the stirred oil to calibrate a temperature sensor above the boiling point of water. The junction of a Type K Thermocouple and the bulb of a reference thermometer sit side by side in the oil. The class notes the thermocouple voltage at several settings up to 150°C and plots a calibration curve.
Organic chemistry classes use the bath for reactions that need steady heat beyond the reach of a water bath. The flask is clamped in the oil with one of the Condensers Allihn fitted on top, which returns the vapour to the flask. Stirring keeps the oil at one temperature around the flask, so the mixture does not scorch on a hot spot.
Frequently Asked Questions
Copper or stainless steel chamber: which should I choose?
Copper conducts heat better, so the chamber wall warms evenly, but it darkens with use. Stainless steel does not tarnish in the same way and is simpler to wipe down. Both are heated and stirred in the same way.
Why must the oil stay below its smoke point?
Above its smoke point oil starts to break down, giving off fumes and darkening. Choose an oil rated well above your working temperature, keep within the bath limit of 150°C and replace oil that has turned dark or thick.
How deep should the flask sit in the oil?
Lower it until the reaction mixture is at or just below the oil surface, and clamp the flask so it does not touch the chamber floor. That way the mixture heats evenly and the flask is not resting on the hottest metal.
How do I clean oil off flasks after use?
Let the flask drain over the bath, then wipe it with paper towel once it is cool enough to hold. Wash it with hot water and detergent, and keep water away from the hot oil, since drops of water make hot oil spit.
Other Heated Baths
- Oil Bath (High Temp) with Stirrer
- Temperature and Precision Control Water Bath
- Hotplate & Magnetic Stirrer
For a quote, use Add To Cart or send us a message through the contact page.