HP Viridia 24 Manufacturer,Supplier and Exporter in India
Product Code : EL-MMS-3888
Jlab Export is a leading HP Viridia 24 Manufacturer,and suppliers in India
The HP Viridia 24 is a multi-parameter patient monitor that JLab supplies. Its functions cover invasive and non-invasive blood pressures, pulse oximetry, temperature, cardiac output, capnography with end tidal CO2, a blood analysis module and an anaesthetic gas module. Internal device interfaces link other equipment, and a thermal array recorder prints traces.
Specifications
| Brand | HP |
| Condition | New |
| Pressures | Invasive and non-invasive blood pressures |
| Gas measurements | Capnography, end tidal CO2, anaesthetic gas module |
| Other parameters | Pulse oximetry, temperature, cardiac output |
| Blood analysis | Blood analysis module |
| Connections | Internal device interfaces |
| Recorder | Thermal array recorder |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Biomedical Engineering Lab Exercises
The monitor gives biomedical engineering students a full set of parameters to identify and test. For the NIBP check, they join the cuff line to the dial of a Sphygmomanometer Aneroid Square Shaped with a T-piece. They then compare the two pressure readings at several points.
For the temperature channel, the probe and a Digital Thermometer go side by side into a beaker of warm water, and students log both readings as it cools. They finish by loading paper in the recorder and printing a test strip.
Frequently Asked Questions
Which measurements can the Viridia 24 handle?
Invasive and non-invasive blood pressures, pulse oximetry, temperature, cardiac output, capnography with end tidal CO2, blood analysis and anaesthetic gas. Which of these are used on a given patient is set by trained staff.
Can the screen language be changed?
Display language is a configuration setting. On monitors of this class the configuration menu is usually protected. A biomedical engineer changes it and checks the other settings before the unit returns to use.
What does the thermal array recorder need?
It prints waveforms and readings on heat-sensitive paper, with no ink or ribbon. Load the roll with the coated side towards the print head, and store spare rolls away from heat and sunlight, which darken them.
Who should service this monitor?
Servicing needs the maker’s service documentation and trained biomedical staff. Keep the user and service manuals with the unit, and log every performance check and repair.
Other Patient Monitors
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026