Multipara Patient Monitor Manufacturer,Supplier and Exporter in India
Product Code : EL-MMS-3883
Jlab Export is a leading Multipara Patient Monitor Manufacturer,and suppliers in India
Blood pressure and oxygen saturation are the two measurements on this monitor. Bright LED digits show the NIBP and SpO2 values, a screen traces the SpO2 waveform, and NIBP can be taken in manual, auto or continuous mode. It stores up to 600 groups of NIBP readings or 10 hours of SpO2 data, for adult, paediatric and neonatal patients.
Specifications
| Parameters | NIBP and SpO2 |
| Display | High-brightness LED readings, SpO2 waveform |
| NIBP modes | Manual, auto and continuous |
| Alarms | Audible and visual, adjustable |
| Data storage | Up to 600 groups of NIBP data, or SpO2 data up to 10 hours |
| Patient groups | Adult, paediatric and neonatal |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals for Nursing Students
Working in pairs, students take each other’s blood pressure on the monitor and then by hand with a Sphygmomanometer (Nylon Cuff) and Stethoscope. They log both results and talk through why readings taken minutes apart differ. They then run the auto mode and watch how the cuff cycles on its own.
For SpO2, one student wears the monitor probe on one finger and a Hand Held Pulse Oximeter on another. The group shines a desk lamp on the probe and then asks the wearer to move the hand. The waveform shows how light and motion disturb the signal.
Frequently Asked Questions
What is the difference between manual, auto and continuous NIBP?
Manual takes one reading when you press start. Auto repeats the measurement at a set interval. Continuous repeats it straight away, one after another, for a short period. Which mode a patient needs is decided by trained staff under the hospital’s protocol.
Why does the cuff size matter?
The cuff must suit the arm. An undersized cuff tends to read high, an oversized one low, and a loose wrap can make the measurement fail or repeat. The monitor covers adult, paediatric and neonatal patients, so keep the matching cuff sizes with it.
Why does the SpO2 reading jump about?
Strong room light on the probe, hand movement, a poorly placed or damaged probe, or a cuff squeezing the same arm can all disturb it. Shade the probe, keep the hand still and put the cuff on the other arm.
Why did the NIBP measurement fail or repeat?
Talking, moving or bending the arm during inflation is the usual cause. A leak in the cuff or hose is the other. Keep the arm still at heart level, check the hose joints, and try again.
Other Patient Monitors
For a quote, use Add To Cart or send us a message through the contact page.