• +91-85699-09696

Patient Multipara Monitor Manufacturer,Supplier and Exporter in India

Patient Multipara Monitor

Product Code : EL-MMS-3887
Jlab Export is a leading Patient Multipara Monitor Manufacturer,and suppliers in India

Built for wards that link beds to a central monitoring system, this monitor has a large 12.1 in colour display with several screen layouts, including a large-font view. A high ECG filter holds back drift and interference, SpO2 reads through low perfusion, and arrhythmia and ST analysis run on board. Drug dose calculation and a dynamic trend are built in.

Specifications

Display12.1 in colour
Patient groupsAdult and paediatric
SpO2Reads through low perfusion
ECG filterHigh filter against drift and interference
AnalysisArrhythmia and ST
FunctionsDrug dose calculation, dynamic trend
Screen layoutsMultiple, with large font option
NetworkCentral monitoring system
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Classroom Demonstrations for ECG and Trends

Biomedical engineering tutors use the monitor to show how ECG filtering changes a trace. Students record a volunteer on a Hand Held Single Channel ECG and compare its strip with the filtered monitor trace, looking at the baseline and the ST segment.

Nursing students count a classmate’s apical beat for a full minute with a Stethoscope and check it against the heart rate on screen. They switch between screen layouts, pick the large-font view, and read the dynamic trend at the end of the session. They also practise the drug calculation screen with example figures from the tutor.

Frequently Asked Questions

Why does the ECG look different with another filter setting?
A stronger filter removes more drift and interference, so the trace looks smoother. It can also reshape the ST segment. ST assessment is normally done on the wider-band setting, as the hospital’s protocol directs.

What is the drug dose calculation for?
It works out figures such as concentration and rate from the values staff enter, saving a separate calculator at the bedside. It does not choose a dose. Prescribing and checking follow the hospital’s own protocol and trained staff.

Can the screen be read from across the room?
Yes. The monitor offers several screen layouts, including one with large fonts, so the main values stay readable at a distance. Staff can pick the layout that suits the bed and the ward.

How do I review the dynamic trend?
Open the trend screen to see how each value has moved over the recent period, then step back through earlier readings. Linked to the central monitoring system, the same data can also be viewed from the nurses’ station.

Other Multipara Monitors

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us