• +91-85699-09696

Vital Sign Monitors Manufacturer,Supplier and Exporter in India

Vital Sign Monitors

Product Code : EL-MMS-3890
Jlab Export is a leading Vital Sign Monitors Manufacturer,and suppliers in India

This bedside monitor shows six standard parameters on one 7 inch colour TFT screen: ECG, non-invasive blood pressure (NIBP), SpO2, respiration, temperature and pulse rate. It draws up to 8 waveform channels, runs on a built-in rechargeable battery and keeps 72 hours of trend graphs and tables. It is set up for adult, paediatric and neonatal patients.

Specifications

Display7 inch colour TFT screen
WaveformsUp to 8 channels
Standard parametersECG, NIBP, SpO2, respiration, temperature, pulse rate
Patient typesAdult, paediatric and neonatal
Trend storage72 hours of trend graphs and tables
Waveform review40 seconds
PowerBuilt-in rechargeable battery
BuildLight and portable
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Skills Lab Practicals with the Monitor

In a nursing skills lab, students work in pairs and take a full set of observations on each other. One clips the SpO2 probe on a finger and wraps the NIBP cuff on the upper arm. The partner then takes a manual reading with a Sphygmomanometer (Nylon Cuff) and a Stethoscope, and the pair discuss why the two figures differ. The temperature probe can be read beside a Clinical Thermometer in the same way.

Biomedical engineering students use the unit for inspection practice. They check the power cord, patient cables and lead wires for cracks, trigger the alarms by removing a probe, and run the monitor on its battery to watch the charge indicator. Cuff placement and lead positions can first be rehearsed on a Multi Functional Patient Care Nursing Manikin.

Frequently Asked Questions

Why does the monitor alarm when nothing seems wrong?
In a training room the usual causes are a loose SpO2 probe, a hand that keeps moving, a cuff wrapped too loosely, or ECG electrodes that have dried out. Check the sensor and its lead first, then the alarm limits. Staff set those limits by the hospital protocol.

What should I check if it will not switch on or shuts down?
See that the mains cord is fully seated and the socket is live, then look at the battery indicator. A rechargeable battery left flat for weeks holds less charge. Charge it fully, and if the fault returns, ask a biomedical technician to test the battery and power supply.

How does the monitor count respiration?
Most bedside monitors count breaths through the ECG electrodes, sensing the small change in chest impedance as the chest rises and falls. Shallow breathing and body movement can upset the count. When heart and breathing rates are close, heartbeats may be counted as breaths, so check the rate by watching the chest.

How do I look back at earlier readings?
The monitor stores 72 hours of trend data as graphs and tables, and offers a 40 second waveform review. Teachers can open the trend screen after a practical to show how each reading changed during the session.

How should the cuff, probes and cables be cleaned?
Wipe them with the cleaner your facility uses for patient equipment and let them dry before storage. Do not soak connectors or pull a cable by its lead. Coil the cables loosely so the wires inside do not crack.

Other Patient Monitoring Equipment

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us