Ward-scale networking sets this multipara monitor apart. Up to 66 beds can share one network, and it links to the hospital information system (HIS). The 12.1 in high-resolution LCD shows large numbers that staff can read from across the room. Digital SpO2 has anti-motion and anti-low-perfusion functions, and 168 hours of trends are kept as tables and graphs.

Specifications

Display12.1 in high-resolution LCD
NumericsLarge number display for viewing from a distance
SpO2Digital, with anti-motion and anti-low-perfusion functions
Trends and storage168 hours, tabular and graphic
NetworkUp to 66 beds, connects with HIS
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises on SpO2 and Networking

To test the SpO2 functions, a student wears the monitor probe and a Finger Tip Pulse Oximeter on two fingers of the same hand. The student taps the hand, then raises the arm for a minute, while the group compares both readings and waveforms. A tabletop Pulse Oximeter System can be added as a third reference.

For a nurses’ station drill, students stand at the far end of the lab and call out the values on the screen. Biomedical engineering students trace how bedside data reach a central station and the HIS, and practise admitting and discharging a mock patient.

Frequently Asked Questions

How does the monitor connect to the hospital information system?
It is built to network up to 66 beds and to connect with an HIS. The hospital IT team and a biomedical engineer usually set the link up together, mapping the monitor data to the right fields in the records system.

Why send readings to the HIS instead of writing them down?
Copying numbers by hand takes nursing time and lets errors creep in. When readings pass straight to the records system, the charted values match what the monitor measured.

Should patient data be cleared before the monitor goes for service?
Yes. Discharge the patient and clear stored records before the unit leaves the ward for repair, loan or disposal. With 168 hours of trends on board, a lot of personal data can sit in the monitor.

How do we keep a networked monitor secure?
Keep it on the hospital’s protected clinical network, not on open Wi-Fi or the internet. Limit who can change settings, and follow the IT department’s rules for software updates.