Small volumes distil more cleanly from a tapered bottom than from a wide round one. These pear-shaped distillation flasks come in 15, 25, 50 and 100 ml. Every size has a B14 socket and a B14 cone, so the flask joins B14 condensers, adapters and thermometers without a reducing piece.

Specifications

BodyPear shaped
UseDistillation of small volumes
Capacities15 ml, 25 ml, 50 ml, 100 ml
SocketB14
ConeB14
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Small-Scale Distillation Practicals

Many college courses now run organic preparations on a small scale to save chemicals and time. After making a few millilitres of a liquid such as cyclohexene from cyclohexanol, students wash and dry the crude product. They then purify it by simple distillation in a 15 or 25 ml flask joined to a Condensers, Liebig with B14 joints.

Teachers often use the 100 ml size to show a solvent being separated from a coloured solute that does not boil. The dye stays behind in the narrow bottom while clear solvent collects in the receiver. Each joint in the set-up is held with one of the Joint Clips, Plastic.

Frequently Asked Questions

Why is a pear shape used for small distillations?
The tapered bottom keeps even the last few millilitres deep enough to cover the heated glass. In a round flask the same liquid spreads thin over a wide base, where it overheats and spatters. A pipette can also reach the residue in the narrow tip.

Why should I stop before the flask boils dry?
A dry flask overheats quickly. Residues can char or decompose, and peroxides left by some ethers can explode when heated dry. Stop while a little liquid remains in the bottom, then lower the heat and let the flask cool.

Why does the thermometer read low with a small sample?
There may not be enough vapour to surround the bulb. The reading settles only when vapour bathes the bulb steadily. Set the bulb just below the point where vapour turns toward the condenser, and record the boiling range only once distillate drips at an even rate.

How do I stop the joints leaking under vacuum?
Wipe the cone and socket clean, spread a thin ring of vacuum grease on the upper part of the cone, and turn it until the joint looks clear. Clip every joint, and use thick-walled vacuum tubing, since thin tubing can collapse or let air in.