Axial Flow Pump Test Rig (code EL-HLE-8982) is a pump test bench in which an axial flow pump, driven by a 3 HP three-phase motor, delivers about 150 LPM around its own water circuit. A pressure gauge, a measuring tank and an energy meter give the head, discharge and electrical input needed for performance tests. JLab builds this axial pump rig in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Pump | Axial flow pump, discharge about 150 LPM |
| Motor | 3 HP, three phase, 400/440 V AC supply |
| Electrical panel | Switch and energy meter for input power |
| Sump tank | M.S. with FRP lining or stainless steel, sized for independent water circulation |
| Measuring tank | M.S. with FRP lining or stainless steel, with standard fittings for measuring discharge |
| Piping | Pipes, pressure relief valve, gate valve and fittings with pressure gauge |
| Quality check | Each test rig is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-HLE-8982 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Why an Axial Flow Pump Gives High Flow at Low Head
The impeller of an axial flow pump works like a propeller inside a pipe: its blades push the water along the line of the shaft instead of throwing it outwards, as a centrifugal impeller does. The result is a large discharge at a low head, so axial pumps are the usual choice where big volumes have to be lifted a short height. The power an axial pump takes is highest at low flow, so during a test the gate valve is closed down in steps and never shut completely.
Reading Head, Discharge and Input Power
At each setting of the gate valve, the pressure gauge gives the delivery head, the rise of water in the measuring tank over a timed interval gives the discharge Q, and the energy meter on the panel gives the electrical input. The hydraulic output is ρgQH, and dividing it by the input gives the overall efficiency of the pump set. On the characteristic curves of an axial pump, head and input power both fall steeply as the flow rises, while efficiency climbs to a peak and drops again.
Other Pump Test Rigs to Compare
- Centrifugal Pump Test Rig — belt-driven centrifugal pump that runs at three speeds from a stepped pulley.
- Reciprocating Pump Test Rig — double-acting piston pump with an air vessel and crank drive.
- Multi Pump Test Rig — curves for eight pump types, with an axial pump as an accessory.
- Multistage Centrifugal Pump Test Rig — two-stage monoblock centrifugal pump with gauges at both stages.
More rigs for flow and pump work sit in Hydrology Lab Equipments, within Mechanical Engineering Lab Equipment.
Request a Quote
Send your enquiry through Add To Cart or our contact page, giving the number of rigs, your choice of FRP-lined M.S. or stainless steel tanks, and the delivery town.
Last updated: 30 October 2026