Schering Bridge Trainer (code EL-AET-1475) is an analog electronics training board for finding the value of an unknown capacitance by the Schering bridge method. A 1 kHz sine-wave oscillator drives the bridge and an audio amplifier with a speaker acts as the null detector, so the balance point is heard rather than read from a meter. JLab builds the trainer at its own works in Ambala, India.

Specifications

ParameterDetail
ExperimentMeasurement of the value of an unknown capacitance by the Schering bridge
Bridge circuitSchering bridge circuit with arm values
Unknown capacitorsThree unknown values, selected by a band switch
Resistance selectionBand switch selecting one of six different resistance values
Balancing controlPotentiometer for balancing the bridge
Signal source1 kHz sine-wave oscillator, output 0–15 Vpp
Null detectorAudio amplifier and speaker
Internal power supply±12 V DC at 100 mA, IC-regulated, internally connected
Mains controlsMains on/off switch, fuse and jewel light
Mains supply230 V ±10%, 50 Hz AC
Patch cordsStackable, with 4 mm spring-loaded plugs, half a metre long
TerminalsTerminals/sockets at the appropriate places on the panel for connections and for observing waveforms
Operating instructionsDetailed, giving the object, theory, design procedures, report suggestions and book references
Weight3 kg (approx.)
DimensionsW 340 x H 110 x D 210
Quality checkEach trainer is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity10 units
Dispatch timeUsually 7–10 working days
Product codeEL-AET-1475
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

How Does It Compare with Other JLab Capacitance Bridges?

ModelAC sourceNull detectorUnknowns and adjustment
This trainer (EL-AET-1475)1 kHz sine-wave oscillator, 0–15 Vpp outputAudio amplifier and speakerThree unknown capacitors on a band switch; six resistance values on a band switch; balancing potentiometer
Schering BridgeBuilt-in 1 kHz sine-wave sourceNull detector with digital displayFive unknown capacitors on a rotary switch; ratio, resistance and capacitance decade dials; teak wood case
DE Sauty BridgeSeparate Bridge Oscillator requiredHigh-impedance headphoneTwo decade resistances and two decade capacitors as the bridge arms; compares the capacitance of two capacitors

Pick this trainer when students should find the null by ear, with the oscillator built into the trainer itself. The Schering Bridge sets its arms on decade dials and shows the null on a digital display, and the DE Sauty Bridge compares two capacitors through a headphone, driven by a separate Bridge Oscillator.

What Is the Schering Bridge Trainer Used For?

The Schering bridge is a four-arm AC bridge for measuring capacitance and a standard experiment in electrical and electronic measurement courses at diploma and engineering level and in BSc physics labs. When the bridge is balanced, the unknown capacitance is calculated from the known values of the other arms, so students practise both the balancing and the bridge equations. The panel sockets also allow the bridge signals to be viewed on an oscilloscope.

What to Specify When Ordering

  • Quantity — the number of trainers for your measurement or electronics lab.
  • Other bridge boards — if the course also covers Wien, Anderson or De Sauty bridges, list those trainers on the same enquiry.
  • Oscilloscope — a separate item; add it to the enquiry if your lab needs one for viewing waveforms.

Frequently Asked Questions

How is the balance point found on this trainer?
By ear. The tone heard from the detector becomes quietest when the potentiometer and the resistance switch bring the bridge to balance, and that setting is used to work out the unknown capacitance.

Why measure capacitance with a Schering bridge?
Its balance conditions do not depend on the supply frequency, and it represents a real capacitor’s losses as well as its capacitance, which is why the method is widely used for testing capacitors and insulation. On this trainer the object of the experiment is the value of the unknown capacitance.

What supply does the trainer need?
It works on 230 V ±10%, 50 Hz AC mains. Inside, a ±12 V DC IC-regulated supply rated at 100 mA is internally connected.

Are operating instructions provided?
Yes. The trainer is backed by detailed operating instructions that set out the object, the theory, the design procedure, suggestions for the report and book references.

What information is needed for an export quotation?
Send the number of trainers, the destination country and port or city, your preferred delivery terms such as FOB or CIF, any packing or labelling needs, and a tender reference if the purchase is for a tender.

Who manufactures the Schering Bridge Trainer?
JLab, the trading name of Jain Laboratory Instruments Pvt Ltd, produces it in Ambala, Haryana, and quotes for it as the maker.

OEM Manufacturer

JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a maker of electronics and electrical measurement trainers in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. This bridge trainer comes from JLab’s own works and not from a trading house, so colleges, polytechnics, dealers and importers deal directly with the manufacturer; every unit is visually inspected before it leaves, and repeat orders go back to the same team. JLab exports worldwide and ships to buyers in every region — Canada in North America, Burkina Faso in West Africa, South Korea in East Asia, Brazil in South America and Jamaica in Central America and the Caribbean, to give a few examples. Details for institutional purchases are on the JLab lab tenders page.

Related Bridge Trainers and Instruments

  • Wien Bridge — measures capacitance by the Wien series and parallel bridge methods, with a 1 kHz oscillator and speaker null detection.
  • Measurement of Inductance and Capacitance — a board for finding unknown capacitors and inductors selected by band switches.
  • Anderson Bridge — the inductance counterpart, measuring the inductance of a coil by the Anderson bridge method.
  • Dual Trace Oscilloscope — a two-channel cathode ray oscilloscope, quoted separately, for viewing waveforms.

Browse the full Analog Electronics Trainer range or all Electronics Lab Equipments.

Request a Quote

To get a quotation, press the Add To Cart enquiry button on this page or write through the contact page with the number of trainers, the delivery destination and any other bridge boards you want quoted together.

Last updated: 22 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us