Two Stage Air Compressor Test Rig Manufacturer,Supplier and Exporter in India
Product Code : EL-TL-10057
Jlab Export is a leading Two Stage Air Compressor Test Rig Manufacturer,and suppliers in India
Two Stage Air Compressor Test Rig (code EL-TL-10057) is a bench for testing a double-cylinder, two-stage air compressor driven by a 2 hp three-phase motor and mounted with it on the air receiver. Pressure gauges at the outlet of both stages, an orifice and water manometer on the intake and an energy meter give the data for volumetric and isothermal efficiency. JLab produces this two-stage compressor rig in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Compressor | Double cylinder, two stage |
| Drive | 2 hp three-phase motor |
| Mounting | Compressor and motor on the air receiver, with delivery valve |
| Controls | Air relief valve and pressure switch |
| Air intake measurement | Air tank and orifice with water manometer |
| Pressure gauges | At the outlet of both stages |
| Other instruments | Digital temperature indicator; energy meter for input power |
| Services required | 440 V, 15 A, three-phase AC with neutral and earthing; hand tachometer; floor space 2.5 m x 1.5 m |
| Documentation | Technical manual |
| Quality check | Each compressor test rig is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-TL-10057 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Why Compress in Two Stages
Raising air to a high pressure in one cylinder makes it very hot, costs extra work and lets more clearance air re-expand, so volumetric efficiency drops. In two stages the first cylinder compresses to an intermediate pressure and the second takes it to delivery pressure. The work saving comes from cooling the air between the stages, which brings the whole process closer to isothermal; with perfect intercooling the total work is least when both stages share the same pressure ratio, so the ideal intermediate pressure is p2 = √(p1 p3) in absolute terms. The gauge at each stage outlet shows the actual split, which can be set against that ideal.
Readings and Efficiencies
The water manometer on the orifice gives the free air delivered, Va, at intake conditions, and the energy meter gives the electrical input. Volumetric efficiency is Va divided by the swept volume of the first-stage cylinder, worked out from its bore, stroke and the speed from the hand tachometer. Isothermal efficiency is p1 Va ln(p3/p1) divided by the input power. Readings are repeated at several delivery pressures set with the delivery valve, while the digital temperature indicator follows the air temperatures.
Other Air Compressor Test Rigs
- Single Stage Air Compressor Test Rig — single cylinder, single stage compressor for comparison with staged compression.
- Air Compressor Test Rig — two-stage, twin cylinder 3 HP compressor mounted on a storage tank.
- Rotary Air Compressor Test Rig — a rotary vane machine in place of pistons.
Find the rest of the compressor and steam rigs in Thermodynamics Lab, within Engineering Lab Equipment.
Request a Quote
Ask for a quotation through Add To Cart or the contact page, giving the quantity and the delivery address.
Last updated: 30 October 2026