• +91-85699-09696

Centrifugal Blower Test Rig Manufacturer,Supplier and Exporter in India

Centrifugal Blower Test Rig

Product Code : EL-TL-10059
Jlab Export is a leading Centrifugal Blower Test Rig Manufacturer,and suppliers in India

Centrifugal Blower Test Rig (code EL-TL-10059) is a spiral-casing blower with three interchangeable impellers, forward curved, backward curved and radial vane, driven by a 1 HP DC motor whose speed is set anywhere from 300 to 3000 RPM. A venturi with water manometer gives the air flow and a second manometer the discharge pressure. JLab makes this blower test rig in Ambala, India.

Specifications

ParameterDetail
BlowerSpiral casing with three interchangeable impellers: forward, backward and radial vanes
Drive motor1 HP DC motor, 3000 RPM
Speed controlDimmer control, 300 to 3000 RPM
Speed measurementDigital speed indicator
Air flow measurementVenturi with water manometer
Discharge pressureWater manometer
Flow controlDischarge pipe with flow control valve
Services required230 V, 5 A, 50 Hz AC supply; floor space about 2 m x 1.5 m x 1.5 m height
DocumentationTechnical manual
Quality checkEach blower test rig is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-TL-10059
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Comparing the Three Impellers

Only the impeller changes between runs, so differences in the curves come from blade shape alone. At a fixed speed the flow control valve on the discharge pipe is opened in steps, and the pressure rise is plotted against air flow for each impeller. Euler’s equation predicts the trend: with backward curved vanes the ideal head falls as flow rises, with radial vanes it stays level, and with forward curved vanes it rises, so the forward curved impeller moves the most air for its size and speed but also draws the most power as the flow grows. The backward curved impeller gives the steadiest, falling characteristic of the three.

Speed and the Fan Laws

The dimmer sets the speed and the digital indicator shows it. For one impeller, repeating the test at several speeds checks the fan laws: flow varies with speed N, pressure rise with N², and air power with N³. Air power at any point is the volume flow from the venturi multiplied by the pressure rise, Q × Δp, with the manometer readings converted from water column to pascals.

Other Blower and Air Flow Rigs

The rig is listed in Thermodynamics Lab among the Engineering Lab Equipment benches.